Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
1.
Journal of Korean Neurosurgical Society ; : 568-673, 2018.
Article in English | WPRIM | ID: wpr-788722

ABSTRACT

OBJECTIVE: Thoracic pedicles have special and specific properties. In particular, upper thoracic pedicles are positioned in craniocaudal plane. Therefore, manipulation of thoracic pedicle screws on the left side is difficult for right-handed surgeons. We recommend a new position to insert thoracic pedicle screw that will be much comfortable for spine surgeons.METHODS: We retrospectively reviewed 33 patients who underwent upper thoracic pedicle screw instrumentation. In 15 patients, a total of 110 thoracic pedicle screws were inserted to the upper thoracic spine (T1–6) with classical position (anesthesiologist and monitor were placed near to patient’s head. Surgeons were standing classically near to patient’s body while patients were lying in prone position). In 18 patients, a total of 88 thoracic pedicle screws were inserted to the upper thoracic spine with the new standing position-surgeons stand by the head of the patient and the anesthesia monitor laterally and under patient’s belt level. All the operations performed by the same senior spine surgeons with the help of C-arm. Postoperative computed tomography scans were obtained to assess the screw placement. The screw malposition and pedicle wall violations were divided and evaluated separately. Cortical penetration were measured and graded at either : 1–2 mm penetration, 2–4 mm penetration and >4 mm penetration.RESULTS: Total 198 screws were inserted with two different standing positions. Of 198 screws 110 were in the classical positioning group and 88 were in the new positioning group. Incorrect screw placement was found in 33 screws (16.6%). The difference between total screw malposition by both standing positions were found to be statistically significant (p=0.011). The difference between total pedicle wall violations by both standing positions were found to be statistically significant (p=0.003).CONCLUSION: Right-handedness is a problem during the upper thoracic pedicle screw placement on the left side. Changing the surgeon’s position standing near to patient’s head could provide a much comfortable position to orient the craniocaudal plane of the thoracic pedicles.


Subject(s)
Humans , Anesthesia , Deception , Head , Pedicle Screws , Posture , Retrospective Studies , Spine , Surgeons , Thoracic Vertebrae
2.
Journal of Korean Neurosurgical Society ; : 568-673, 2018.
Article in English | WPRIM | ID: wpr-765292

ABSTRACT

OBJECTIVE: Thoracic pedicles have special and specific properties. In particular, upper thoracic pedicles are positioned in craniocaudal plane. Therefore, manipulation of thoracic pedicle screws on the left side is difficult for right-handed surgeons. We recommend a new position to insert thoracic pedicle screw that will be much comfortable for spine surgeons. METHODS: We retrospectively reviewed 33 patients who underwent upper thoracic pedicle screw instrumentation. In 15 patients, a total of 110 thoracic pedicle screws were inserted to the upper thoracic spine (T1–6) with classical position (anesthesiologist and monitor were placed near to patient’s head. Surgeons were standing classically near to patient’s body while patients were lying in prone position). In 18 patients, a total of 88 thoracic pedicle screws were inserted to the upper thoracic spine with the new standing position-surgeons stand by the head of the patient and the anesthesia monitor laterally and under patient’s belt level. All the operations performed by the same senior spine surgeons with the help of C-arm. Postoperative computed tomography scans were obtained to assess the screw placement. The screw malposition and pedicle wall violations were divided and evaluated separately. Cortical penetration were measured and graded at either : 1–2 mm penetration, 2–4 mm penetration and >4 mm penetration. RESULTS: Total 198 screws were inserted with two different standing positions. Of 198 screws 110 were in the classical positioning group and 88 were in the new positioning group. Incorrect screw placement was found in 33 screws (16.6%). The difference between total screw malposition by both standing positions were found to be statistically significant (p=0.011). The difference between total pedicle wall violations by both standing positions were found to be statistically significant (p=0.003). CONCLUSION: Right-handedness is a problem during the upper thoracic pedicle screw placement on the left side. Changing the surgeon’s position standing near to patient’s head could provide a much comfortable position to orient the craniocaudal plane of the thoracic pedicles.


Subject(s)
Humans , Anesthesia , Deception , Head , Pedicle Screws , Posture , Retrospective Studies , Spine , Surgeons , Thoracic Vertebrae
3.
Clinics in Orthopedic Surgery ; : 310-316, 2017.
Article in English | WPRIM | ID: wpr-96458

ABSTRACT

BACKGROUND: This study compares the clinical and radiological results of three most commonly used dynamic stabilization systems in the field of orthopedic surgery. METHODS: A total of 71 patients underwent single-level posterior transpedicular dynamic stabilization between 2011 and 2014 due to lumbar degenerative disc disease. Three different dynamic systems used include: (1) the Dynesys system; (2) a dynamic screw with a PEEK rod; and (3) a full dynamic system (a dynamic screw with a dynamic rod; BalanC). The mean patient age was 45.8 years. The mean follow-up was 29.7 months. Clinical and radiological data were obtained for each patient preoperatively and at 6, 12, and 24 months of follow-up. RESULTS: Clinical outcomes were significantly improved in all patients. There were no significant differences in the radiological outcomes among the groups divided according to the system used. Screw loosening was detected in 2 patients, and 1 patient developed screw breakage. All patients with screw loosening or breakage underwent revision surgery. CONCLUSIONS: Each procedure offered satisfactory outcome regardless of which system was applied.


Subject(s)
Humans , Follow-Up Studies , Intervertebral Disc Degeneration , Orthopedics , Pedicle Screws , Retrospective Studies
4.
Asian Spine Journal ; : 348-355, 2017.
Article in English | WPRIM | ID: wpr-62206

ABSTRACT

STUDY DESIGN: A retrospective study investigating decrease in the nucleus pulposus signal intensity or disc height on magnetic resonance imaging (MRI) and disc degeneration. PURPOSE: Although a degenerated disc cannot self-regenerate, distraction or stabilization may provide suitable conditions for rehydration and possible regeneration. This study aimed to evaluate clinical outcomes and disc regeneration via MRI in a series of patients with degenerative disc disease (DDD) who underwent lumbar stabilization with a dynamic stabilization system (DSS). OVERVIEW OF LITERATURE: A dynamic system provides rehydration during early DDD. METHODS: Fifty-nine patients (mean age, 46.5 years) who undedwent stabilization with DSS for segmental instability (painful black disc) between 2004 and 2014 were retrospectively evaluated. All patients underwent MRI preoperatively and 12 months postoperatively. Intervertebral disc (IVD) degeneration grades at the implanted segment were categorized using the Pfirrmann classification system. Patients were followed for a mean of 6.4 years, and clinical outcomes were based on visual analog scale (VAS) and Oswestry disability index (ODI) scores. RESULTS: Significant improvements in back pain VAS and ODI scores from before surgery (7 and 68%, respectively) were reported at 6 (2.85 and 27.4%, respectively) and 12 months postoperatively (1.8 and 16.3%, respectively). Postoperative IVD changes were observed in 28 patients. Improvement was observed in 20 patients (34%), whereas progressive degeneration was observed in eight patients (13.5%). Thirty-one patients (52.5%) exhibited neither improvement nor progression. Single Pfirrmann grade improvements were observed in 29% of the patients and two-grade improvements were observed in 5%. CONCLUSIONS: Our observations support the theory that physiological movement and a balanced load distribution are necessary for disc regeneration. We conclude that DSS may decelerate the degeneration process and appears to facilitate regeneration.


Subject(s)
Humans , Back Pain , Classification , Dichlorodiphenyldichloroethane , Fluid Therapy , Intervertebral Disc , Intervertebral Disc Degeneration , Magnetic Resonance Imaging , Regeneration , Retrospective Studies , Visual Analog Scale
5.
Asian Spine Journal ; : 767-770, 2016.
Article in English | WPRIM | ID: wpr-164182

ABSTRACT

The technique we describe was developed for cervical foraminal stenosis for cases in which a keyhole foraminotomy would not be effective. Many cervical stenosis cases are so severe that keyhole foraminotomy is not successful. However, the technique outlined in this study provides adequate enlargement of an entire cervical foraminal diameter. This study reports on a novel foraminal expansion technique. Linear drilling was performed in the middle of the facet joint. A small bone graft was placed between the divided lateral masses after distraction. A lateral mass stabilization was performed with screws and rods following the expansion procedure. A cervical foramen was linearly drilled medially to laterally, then expanded with small bone grafts, and a lateral mass instrumentation was added with surgery. The patient was well after the surgery. The novel foraminal expansion is an effective surgical method for severe foraminal stenosis.


Subject(s)
Humans , Constriction, Pathologic , Foraminotomy , Methods , Transplants , Zygapophyseal Joint
6.
Journal of Korean Neurosurgical Society ; : 410-413, 2016.
Article in English | WPRIM | ID: wpr-45405

ABSTRACT

Lumbar radiculopathy is generally caused by such well-recognized entity as lumbar disc herniation in neurosurgical practice; however rare pathologies such as thrombosed epidural varix may mimic them by causing radicular symptoms. In this case report, we present a 26-year-old man with the complaint of back and right leg pain who was operated for right L4-5 disc herniation. The lesion interpreted as an extruded disc herniation preoperatively was found to be a thrombosed epidural varix compressing the nerve root preoperatively. The nerve root was decompressed by shrinking the lesion with bipolar thermocoagulation and excision. The patient's complaints disappeared in the postoperative period. Thrombosed lumbar epidural varices may mimic lumbar disc herniations both radiologically and clinically. Therefore, must be kept in mind in the differential diagnosis of lumbar disc herniations. Microsurgical techniques are mandatory for the treatment of these pathologies and decompression with thermocoagulation and excision is an efficient method.


Subject(s)
Adult , Humans , Decompression , Diagnosis, Differential , Electrocoagulation , Leg , Methods , Pathology , Postoperative Period , Radiculopathy , Varicose Veins
SELECTION OF CITATIONS
SEARCH DETAIL